SNE2000-P, SNE2000-S, SNE2000Q-P and
SNE2000Q-S
Single Line SDSL Network Extender Providers and Subscribers with CAP or 2B1Q Encoding
1.0 INSTALLATION
1.1 Unpack and Inspect the Equipment
The following components should be included:
1SNE2000
1power supply
If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1-
877-638-2638 (1-603-427-0600 for international customers) or [email protected].
1.2 Power Up the SNE2000
Plug the power supply into the Power Adapter port on the back of the SNE2000 and connect it to
your power source. Verify that the Power LED on the front of the SNE2000 is illuminated.
Installation Instructions
CAUTION
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when
handling this equipment.
NOTE
Upon start up, the Ethernet link will remain disabled (as indicated by solid illumination of the
Ethernet Rx, Tx, and Lnk LEDs) until the SDSL connection has been established.
220-0000095 rev02 SNE2000(Q) Installation Pa
g
e 1 of 7
Zobrazit stránku 0
1 2 3 4 5 6 7

Shrnutí obsahu

Strany 1 - SNE2000Q-S

SNE2000-P, SNE2000-S, SNE2000Q-P and SNE2000Q-S Single Line SDSL Network Extender Providers and Subscribers with CAP or 2B1Q Encoding 1.0 INST

Strany 2 - 1.3 Configure the SNE2000

1.3 Configure the SNE2000 Configuration switches for the SDSL port are on the back of the SNE2000, numbered from left to right, 1-4. 1.3.1 B

Strany 3 - 1.4 Connect the SDSL Line

1.3.2 Ethernet Duplex Mode Switch 4: SNE2000-P, SNE2000-S, SNE2000Q-P and SNE2000Q-S The Ethernet link can be configured at either Full Duplex or

Strany 4

particular bandwidth will support, the units may not link up or, if they do achieve link, traffic quality may be affected (e.g., packets may be droppe

Strany 5 - 2.0 ADDITIONAL INFORMATION

2.0 ADDITIONAL INFORMATION 2.1 LED Indications NOTEFor most applications, the SNE2000 connects to a PC using a straight-through Ethernet ca

Strany 6

Ethernet Rx flashing amber Ethernet activity The SNE2000 is receiving data from the Ethernet network. solid amber heavy Rx traffic The SNE2000 is re

Strany 7 - 2.2.2 Industry Canada

(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.) 2.2 Regulatory Compli