1
TNE1544 and TNE1584
T1 Network Extenders Installation Instructions
Document Number TNE1-A2-GN14-20
July 2005
Contents
Software and Firmware License Agreement ................................................. 2
Introduction to the TNE1544 and TNE1584 .................................................. 4
Package Contents ......................................................................................... 4
Release Notes .............................................................................................. 4
Powering Up the Network Extender .............................................................. 5
Connecting the T1 Lines ............................................................................... 6
Connecting the Ethernet Lines ..................................................................... 7
LED Indicators .............................................................................................. 8
Web Interface ................................................................................................ 10
Command Line Interface ............................................................................... 14
Resetting the Network Extender to Factory Defaults .................................... 15
Connector Pin Assignments ......................................................................... 16
Specifications ................................................................................................ 18
EMI Notices .................................................................................................. 19
ACTA Customer Information ......................................................................... 19
Supplier's Declaration of Conformity ............................................................. 21
Notice to Users of the Canadian Telephone Network ................................... 21
Important Safety Instructions ........................................................................ 22
Product Documentation Online ..................................................................... 23
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - Contents

1TNE1544 and TNE1584T1 Network Extenders Installation InstructionsDocument Number TNE1-A2-GN14-20July 2005ContentsSoftware and Firmware License Agreem

Strany 2

10Web InterfaceThe network extender’s integral Network Management System (NMS) lets you configure and monitor the network extender using a standard we

Strany 3

11Web Interface System Requirements Web Browser – Required for running NMS. Compatible web browsers include, but are not limited to, Microsoft Intern

Strany 4 - Release Notes

1210. Click on >> Next >>. The login dialog box appears. Log in using: The NMS home page appears. Username: superuserPassword: Password

Strany 5

13From this screen you can: Click on . . . To configure . . . Management Config. IP Address, Subnet Mask, Default Gateway, Inband Management VL

Strany 6 - Connecting the T1 Lines

14Command Line InterfaceThe network extender can be managed with a Command Line Interface (CLI) through either a direct PC to COM (Communication) Port

Strany 7 - Connecting the Ethernet Lines

15Logging Into the CLIOnce your terminal emulation program has been launched, device information is displayed, followed by a request for username and

Strany 8 - LED Indicators

16Connector Pin AssignmentsT1 RJ48C Pin Assignments Ethernet Pin Assignments Table 3. T1 RJ48C Pin AssignmentsPin FunctionPin 1 Rx R

Strany 9 - Table 2. LEDs (2 of 2)

17DB9 to 8-Pin Modular Adapter PinoutsTo connect the COM port to the DB9 serial port of a PC, use an adapter wired as shown: Pins not shown are unuse

Strany 10 - Web Interface

18SpecificationsSpecifications are subject to change without notice.Table 6. SpecificationsSpecification CriteriaBandwidth/Distance Up to 1.5 Mbps per

Strany 11 - Procedure

19EMI NoticesUnited States – EMI Notice:This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to P

Strany 12

2Software and Firmware License Agreement The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmwa

Strany 13

20A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and re

Strany 14 - Command Line Interface

21Supplier's Declaration of ConformityPlace of Issue: Paradyne Corporation8545 126th Avenue NorthLargo, FL 33773-1502USADate of Issue: 15 Ma

Strany 15 - Logging Into the CLI

22Important Safety Instructions1. Read and follow all warning notices and instructions marked on the product or included in the manual.2. Do not allow

Strany 16 - Connector Pin Assignments

23Product Documentation OnlineComplete documentation for Paradyne products is available at www.paradyne.com. Select Support → Technical Manuals.To ord

Strany 17

24*TNE1-A2-GN14-20**TNE1-A2-GN14-20*

Strany 18 - Specifications

35. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Paradyne make

Strany 19 - EMI Notices

4Introduction to the TNE1544 and TNE1584Paradyne's TNE1544 and TNE1584 are loop bonding network extenders for Paradyne's 12000 and 4000 IP B

Strany 20

5Powering Up the Network ExtenderThe DC power terminal block on the network extender has five terminals: two positive, two negative, and one ground. O

Strany 21

6Connecting the T1 LinesThe primary feature of the network extender is loop bonding capability, although both the provider and subscriber units are ab

Strany 22 - Important Safety Instructions

7Single T1 ConnectionA single line connection can be established between a subscriber unit and any Paradyne T1 provider unit, regardless of loop bondi

Strany 23 - Product Documentation Online

8LED IndicatorsTable 2. LEDs (1 of 2)LED State Indication Additional Information10/100 Ethernet Connections Lnk/ActPulsing GreenStandard operation Tra

Strany 24 - *TNE1-A2-GN14-20*

9T1 Connections Lnk/Alm (Ports 1–4 or 1–8)Flashing Green*T1 connection is established and activeTraffic is flowing.Solid GreenT1 link A connection exi